Block E: Fluid Power Systems (21 questions)
Hydraulic basics
- Pascal: pressure acts equally in all directions. Pumps make flow; resistance makes pressure.
- Force = P x A; speed = Q / A; area = pi x D squared / 4. Rod side: faster, less force.
- Pump flow = displacement x r/min. Motor speed = flow / displacement. kW = MPa x L/min / 60.
Valves
- Relief: normally closed, limits system pressure; flow over it = heat. Reducing: normally open, limits a branch.
- Counterbalance holds a vertical load. Pilot-operated check holds without leakage. Sequence: second actuator after set pressure.
- Tandem centre unloads the pump and holds the actuator. Meter-out for overrunning loads.
Accumulators and fluid
- Precharge with dry nitrogen only. Bleed the fluid side to zero before opening lines.
- Contamination causes most failures. ISO 4406 counts at 4, 6 and 14 micrometres.
- Milky = water or air. Noise worse when cold = suction restriction. Normal tank about 50 to 60 degrees C.
- Drift that stops with the lines capped at the valve = spool leakage. Jerky after a repair = air.
- Never feel for leaks with a hand: use cardboard.
Pneumatics and vacuum
- FRL order: filter, regulator, lubricator. Ports: 1 supply, 2 and 4 outlets, 3 and 5 exhausts.
- Meter-out for smooth motion; quick exhaust for speed. Shuttle = OR; two-pressure = AND.
- Branches off the top of the header. Once lubricated, keep lubricating. Clogged silencer = slow actuator.
- Vacuum force = pressure difference x area / safety factor. Never aim compressed air at a person.
Independent study guide. Not affiliated with or endorsed by the Red Seal Program or any apprenticeship authority.