Scenario questions give one clue that points to the cause. Learn these pairs.
| Symptom | Most likely cause |
|---|---|
| Pump sounds like gravel, pressure unsteady | Cavitation: suction restriction, low tank level, hot liquid, throttled suction valve |
| Pump flow and amps both low, head below curve | Worn wear rings or impeller (internal recirculation) |
| Pump misalignment keeps coming back | Pipe strain on the casing |
| Motor current high at design flow | Larger impeller than ordered, or a heavier or thicker liquid than designed |
| New mechanical seal leaks at once | Run dry, damaged at installation, or wrong setting length |
| Check valve bangs when the pump stops | Water hammer: slow-closing check valve |
| Fan vibration at 1X, mostly radial | Unbalance, often from build-up on the wheel |
| Fan flow and amps both falling at the same speed | Blocked filter, closed damper or fouled wheel (higher system resistance) |
| Centrifugal fan moves little air after a motor change | Running backwards |
| High axial vibration with 1X and 2X | Misalignment (check hot: thermal growth and pipe strain) |
| Many running-speed harmonics | Looseness |
| 120 Hz that stops the instant power is cut | Electrical fault in the motor |
| Rising high-frequency acceleration, velocity unchanged | Early rolling bearing defect |
| Washboard pattern on bearing races (VFD motor) | Fluting from shaft currents |
| Bearing hot right after greasing | Over-greasing |
| Fretting on the shaft under the inner ring | Loose fit: worn shaft or wrong fit |
| Wear path on one side of the race | Misalignment or axial preload (no floating bearing) |
| Noisy bearings after long storage | False brinelling: shafts not turned in storage |
| V-belts turn over in the grooves | Misaligned sheaves or worn grooves |
| New V-belts squeal after a day | Run-in stretch: re-tension |
| Belt runs off only when loaded | Off-centre loading at the transfer point |
| Material dropping along the return | Carryback past a worn or badly set belt cleaner |
| Gear contact at one end of the teeth | Shafts not parallel (misalignment) |
| Pitting along the gear pitch line | Surface fatigue: overload, poor lubrication or misalignment |
| Gearbox hot, oil above the full mark | Overfilling: churning |
| Hydraulic oil milky | Water or air in the fluid |
| Hydraulic pump noisy, worse when cold | Cavitation: clogged strainer and thick oil |
| Hydraulic system hot, gauge at relief pressure while idle | Flow over the relief valve: needs unloading or a compensated pump |
| Cylinder drifts; holds when lines are capped at the valve | Directional valve spool leakage |
| Cylinder jerky after a seal change | Air in the system: bleed it |
| Two cylinders on one valve move unevenly | Oil takes the easiest path: use a flow divider or mechanical link |
| Pneumatic actuator slow, silencer oily and black | Clogged silencer from over-lubrication |
| Water at air tools | Failed drains or dryer |
| Compressor short cycles | Receiver full of water or narrow pressure switch band |
| Compressor stage runs hot and slow to pump up | Leaking or broken valve in that stage |
| Vacuum cups drop parts, vacuum low | Worn cups, leaks or blocked filter |
| Motor trips after pulleys changed for more airflow | Power rises with speed cubed |
| Motor hot at low VFD speed, current normal | Shaft fan moves less air at low speed |
Independent study guide. Not affiliated with or endorsed by the Red Seal Program or any apprenticeship authority.