Red Seal 433A Millwright Exam Prep 2027-2028
Free extras for readers of the book by Daniel R. Wexborne. No sign-in, no codes.

Troubleshooting Guide

Scenario questions give one clue that points to the cause. Learn these pairs.

SymptomMost likely cause
Pump sounds like gravel, pressure unsteadyCavitation: suction restriction, low tank level, hot liquid, throttled suction valve
Pump flow and amps both low, head below curveWorn wear rings or impeller (internal recirculation)
Pump misalignment keeps coming backPipe strain on the casing
Motor current high at design flowLarger impeller than ordered, or a heavier or thicker liquid than designed
New mechanical seal leaks at onceRun dry, damaged at installation, or wrong setting length
Check valve bangs when the pump stopsWater hammer: slow-closing check valve
Fan vibration at 1X, mostly radialUnbalance, often from build-up on the wheel
Fan flow and amps both falling at the same speedBlocked filter, closed damper or fouled wheel (higher system resistance)
Centrifugal fan moves little air after a motor changeRunning backwards
High axial vibration with 1X and 2XMisalignment (check hot: thermal growth and pipe strain)
Many running-speed harmonicsLooseness
120 Hz that stops the instant power is cutElectrical fault in the motor
Rising high-frequency acceleration, velocity unchangedEarly rolling bearing defect
Washboard pattern on bearing races (VFD motor)Fluting from shaft currents
Bearing hot right after greasingOver-greasing
Fretting on the shaft under the inner ringLoose fit: worn shaft or wrong fit
Wear path on one side of the raceMisalignment or axial preload (no floating bearing)
Noisy bearings after long storageFalse brinelling: shafts not turned in storage
V-belts turn over in the groovesMisaligned sheaves or worn grooves
New V-belts squeal after a dayRun-in stretch: re-tension
Belt runs off only when loadedOff-centre loading at the transfer point
Material dropping along the returnCarryback past a worn or badly set belt cleaner
Gear contact at one end of the teethShafts not parallel (misalignment)
Pitting along the gear pitch lineSurface fatigue: overload, poor lubrication or misalignment
Gearbox hot, oil above the full markOverfilling: churning
Hydraulic oil milkyWater or air in the fluid
Hydraulic pump noisy, worse when coldCavitation: clogged strainer and thick oil
Hydraulic system hot, gauge at relief pressure while idleFlow over the relief valve: needs unloading or a compensated pump
Cylinder drifts; holds when lines are capped at the valveDirectional valve spool leakage
Cylinder jerky after a seal changeAir in the system: bleed it
Two cylinders on one valve move unevenlyOil takes the easiest path: use a flow divider or mechanical link
Pneumatic actuator slow, silencer oily and blackClogged silencer from over-lubrication
Water at air toolsFailed drains or dryer
Compressor short cyclesReceiver full of water or narrow pressure switch band
Compressor stage runs hot and slow to pump upLeaking or broken valve in that stage
Vacuum cups drop parts, vacuum lowWorn cups, leaks or blocked filter
Motor trips after pulleys changed for more airflowPower rises with speed cubed
Motor hot at low VFD speed, current normalShaft fan moves less air at low speed

Independent study guide. Not affiliated with or endorsed by the Red Seal Program or any apprenticeship authority.